Symbols Call
+61 3 9383 6668

V38

V30 Commercial Kitchen Exhaust Fan Cyclo Made

V38

Australian made, the V38 vertical exhaust fan from Cyclo is designed for use in demanding commercial kitchen environments. Manufactured specially to comply with EPA requirements for vertical exhaust configuration and low pollution, the fan features mixed flow impellers that are constructed from aluminium alloy for maximum airflow at high pressure levels.

Product Graph
Cyclo Made Aust. Pty. Ltd.
Section Dimensions (mm)
A 710
B 590
C 143
D 40
E 390
F 455
Typical Industries & Applications :
  • Hospitality | Commercial Kitchens, Food Trucks, Mobile Food Containers
  • Manufacturing | Welding, Powder Coating, Spray Painting, Glue Works, Fibre Glassing
  • Warehousing / Office | Ablution Block, Heat Extraction
  • Extraction of Heat, Toxic Gas and Hazardous Gas options
Description Vertical Exhaust Fan
Model V38
Internal Flange Diameter 385 mm
Fixing Vertical, Roof Mounted
Features

High performing, robust and light weight
Locally owned and manufactured in Melbourne (Australia) since 1947
EPA Compliant, Australian & NZ Standards Compliant

Impeller

Each impeller is individually designed and manufactured to precise specifications for maximum airflow at high pressure
Hand crafted and balanced
Aluminium alloy
Mixed flow type impellers (axial flow and centrifugal design)

Enclosure

Galvanized steel casing and waste resistant motor enclosures
Motor mounted outside airstream
Supplied with associated flanges

Motor Typical CMG, Typical WEG
Phase(s) Single and Three Phase
Custom Motors

Hazard Area Motors
– Ex ‘d’ Flame, Ex ‘e’ Increased Safety, Ex ‘n’ Non-Sparking, Dust Ignition Proof, Bush Fire Code Compliant

Circuit Breaker

Separate Current rated circuit breaker (IEC/EN 60947 approved) must be installed between the motor and building power supply.
Circuit breaker overload should be set to suit motor’s amp draw.

Control Options

5A Variable Speed Switch (Available)
2 Speed Switch (N/A)
Cyclo VSD Plug-Ins (Available)
(Plug ins available: Temperature sensor, CO2 sensor, Airflow / Pressure sensor, Smoke sensor)

Weight 35 – 40kg
Installation

Fan Unit: Roof Plumber, Canopy Maintenance / Installer
Electrical Connections: Licensed electrician

Transport

Top load only
Ensure impeller has not been exposed to wet weather.
Any water inside the motor housing can damage the motor.

Explore Models