Specifically made for commercial kitchens, the V46 vertical fan features individually designed and manufactured impellers that provide maximum airflow at high pressure levels. The fan also complies with EPA requirements, including low pollution and vertical exhaust configuration.
| Model Number | Fan Speed Rev/min | KW | Amps +or-10% | Volts | Noise Level (dBA)* | Motor Shaft mm | IP Rating |
|---|---|---|---|---|---|---|---|
| V46-376-SP | 900 | 0.37 | 2.50 | 240 | 53 | 16 | 44 |
| V46-376-3P | 900 | 0.37 | 1.26 | 415 | 53 | 19 | 55 |
| V46-374-SP** | 1400 | 0.37 | 2.30 | 240 | 63 | 16 | 44 |
| V46-374-3P | 1400 | 0.37 | 1.05 | 415 | 63 | 14 | 55 |
| V46-556-3P | 900 | 0.55 | 1.70 | 415 | 54 | 19 | 55 |
| V46-554-SP | 1400 | 0.55-0.75 | 4.30 | 240 | 64 | 16 | 44 |
| V46-554-3P | 1400 | 0.55 | 1.37 | 415 | 64 | 19 | 55 |
| V46-756-SP | 900 | 0.75 | 4.70 | 240 | 55 | 16 | 44 |
| V46-756-3P | 900 | 0.75 | 1.92 | 415 | 55 | 24 | 55 |
| V46-754-SP | 1400 | 0.75 | 4.30 | 240 | 66 | 16 | 44 |
| V46-754-3P | 1400 | 0.75 | 1.61 | 415 | 66 | 19 | 55 |
| V46-114-3P | 1400 | 1.1 | 2.37 | 415 | 70 | 24 | 55 |
| V46-154-3P | 1400 | 1.5 | 3.20 | 415 | 72 | 24 | 55 |
* Approx noise level @ 3 meters (dBA)
** Variable speed controllable with Variable Speed Switch (VSS)
Energy Efficiency, NCC/BCA Vol. 1, Section J compliant + 2019
NOTE: All fans may be controlled with a Cyclo Variable Speed Drive or other control switches. We recommend all speed control units and switches to be used only with products supplied by Cyclo Fans.
| Section | Dimensions (mm) |
|---|---|
| A | 845 |
| B | 610 |
| C | 130 |
| D | 40 |
| E | 460 |
| F | 525 |
| Description | Vertical Exhaust Fan |
|---|---|
| Model | V46 |
| Internal Flange Diameter | 460 mm |
| Fixing | Vertical, Roof Mounted |
| Features | High performing, robust and light weight |
| Impeller | Each impeller is individually designed and manufactured to precise specifications for maximum airflow at high pressure |
| Enclosure | Galvanized steel casing and waste resistant motor enclosures |
| Motor | Typical Regal, Typical WEG |
| Phase(s) | Single Phase & Three Phase |
| Custom Motors | Hazard Area Motors |
| Circuit Breaker | Separate Current rated circuit breaker (IEC/EN 60947 approved) must be installed between the motor and building power supply. |
| Control Options | 5A Variable Speed Switch (Available) |
| Weight | 40 – 45kg |
| Installation | Fan Unit: Roof Plumber, Canopy Maintenance / Installer |
| Transport | Top load only |